Showing posts with label Siemens Automation. Show all posts
Showing posts with label Siemens Automation. Show all posts

Software PLC - SIMATIC WinAC RTX 2008

Labels: , , , ,


WinAC RTX 2008 is used when high performance, high data volumes and at the same time hard real time are required for the automation task. The optimized runtime system supports the processing of extensive and demanding PC applications in parallel with the control task. The performance of WinAC RTX 2008 can be scaled across the PC platform.


Applications range from machine-level control tasks with rugged embedded PCs to high-end applications on PCs with enhanced performance (e.g. SIMATIC Rack PCs).


Platforms

SIMATIC WinAC RTX 2008 runs on standard PCs wit Windows XP Professional.yet excellently fits to SIMATIC Industrial PCs.In particular, the use on embedded PC platforms such as the SIMATIC Microbox PC 427B or Panel PC 477B with Windows XP Embedded results in cost-effective and very rugged solutions.The Microbox PC 427B is characterized by its diskless and fanless operation. WinAC RTX 2008 uses the main memory of the PCs and offers program backup on the hard disk. Non-cyclic data such as production parameters or recipe data can be stored permanently on the PC's hard disk with the help of system functions (SFC 82 – 84). In addition, all data can be held retentively in conjunction with an uninterruptible power supply (UPS).


I/O connection

Employing WinAC RTX 2008 it is possible to connect the I/O via PROFINET. This requires either the integrated Ethernet interface of the SIMATIC PC or a CP 1616 (PCI) or CP 1604 (PCI-104) communications processor.Open User Communication permits open communication of WinAC RTX 2008 via TCP and UDP. Open data exchange with any communication partner via the PROFINET interface is possible. WinAC RTX 2008 makes use of the TSEND/TRECV blocks for this purpose; they are available as library for all SIMATIC S7 CPUs. In addition I/O can be connected via PROFIBUS DP at up to 12 Mbit/s via the integral DP interface of the SIMATIC PCs or via communications processors (CP 5611 A2/5613 A2). Up to four PROFIBUS lines can be operated with up to 500 slaves.


Isochronous mode

In addition, with its PROFIBUS interfaces WinAC RTX 2008 also supports the system function isochronous mode. With isochronous mode, high-speed, time-dependent applications such as closed-loop controls can also be implemented with distributed I/O. This means that in addition to the control job other functions can be integrated into a PC or smaller, more economical PCs can be used for the same job.


Retentivity

On exiting, WinAC RTX 2008 saves all the data declared as retentive to the hard disk. In order to ensure a defined shutdown of the Software PLC in the event of an unexpected failure of the PC voltage supply, an uninterruptible power supply (UPS, e.g. SITOP DC UPS) can be used. SIMATIC PCs with integrated, non-volatile memory enable up to 128 KB of retentive data to be stored in the event of voltage dip, regardless of the file system. For SIMATIC PCs without integrated, non-volatile memory, the WinAC NV128 plug-in card is available. This enables up to 128 KB of retentive data to be stored. Depending on the version of the PC, however, the use of a UPS may be necessary.
Bahasa: Software ini sangat cocok jika dimiliki oleh perusahaan-perusahaan sistem integrator atau system developer yang menggunakan SIEMENS.






Siemens releases Simatic WinAC RTX F software controller for PC-based automation

Labels: , , , , ,

SIEMENS has released the Simatic WinAC RTX F, a fail-safe software controller for PC-based automation, allowing safety-related tasks to be performed via PC.According to Siemens, the Simatic WinAC RTX F is a Windows XP or eXP-based controller with an optimised runtime system to process extensive PC applications simultaneously.

Like the modular Simatic S7 controllers, the engineering software is Step 7, supplemented by the Distributed Safety option package for safety-related applications.Siemens claims its Simatic WinAC RTX F software controller is suited for high-performance tasks with substantial data volumes and simultaneous, demanding real-time requirements.

When it is used in dual-core processor systems, one core is used for Windows application, and the other for the Simatic WinAC RTX F controller.The Simatic WinAC RTX F fail-safe software controller can be installed on all current x86 PC hardware platforms, such as Simatic PCs.Simatic WinAC RTX F can be expanded using the safety-oriented peripherals ET 200S, ET 200M, and ET 200pro with IP67 degree of protection, or with the safety-oriented ET 200eco block I/O with IP67 degree of protection.

Buat informasi detail, silahkan check http://www.automation.siemens.com/simatic/pcbased/html_76/produkte/pc-based/based.htm

Brosurnya: Right click and Save as > http://www.automation.siemens.com/salesmaterial-as/brochure/en/brochure_simatic-controller_en.pdf







Simatic S7 to Logix5000 Application Conversion Guide

Labels: , , , , , ,

I have question about conversion PLC program from Siemens S7 to RSlogix, Is it possible?

Answer: Yes it's possible to do it.

This user manual provides guidance for users and engineers who have used control systems based on one of these two platforms:
• Siemens S7 Controller
• Rockwell Automation Logix Programmable Automation Controller
(PAC)
And in addition:
• have a desire or a need to take advantage of the PAC features, or are in
the early stages of migrating a S7 to Logix.
• have specific STEP 7 program code that they wish to convert to
effective and efficient RSLogix 5000 code.
Use this manual to help you adopt good practices and to avoid common mistakes when converting the project to Logix.

For more in detail, please download this manual. Click Here. or you can copy and paste url: http://literature.rockwellautomation.com/idc/groups/literature/documents/ap/logix-ap008_-en-p.pdf to your browser.




Siemens Simatic S7 (Photo PLC Hardware)

Labels: , , ,

Bagi anda yang belum tahu mengenai Hardware PLC, Berikut ini beberapa type PLC Siemens.

Siemens Simatic S7

Classic Automation has a significant amount of surplus Siemens Simatic S7 parts in inventory. We also have extensive test systems and experience to provide you with reliable and high quality Simatic S7 parts.This includes Siemens Simatic S7-200, S7-300 and S7-400. You can search our on-line inventory database to find the surplus Siemens Simatic S7 parts that you require.


We have extensive Siemens S7 test systems and all of our Siemens S7 parts have a 1-year warranty.

Siemens S7-300 testing

Siemens S7-400 testing

Siemens Simatic S5 Migration to Simatic S7
Classic Automation has teamed up with Softwerk, a certified Siemens Solutions provider with a great deal of experience in migrating S5 systems, to provide you with S7 migration solutions that are cost effective and meets your production needs. For more information go to Siemens Simatic S5 Migration to Simatic S7.

Please visit Website, Click Here! For more information.

Langanan Berita : http://feeds2.feedburner.com/belajarplcdanscadaok





How is the SIWAREX MS calibrated with SIWATOOL MS?

Labels: , , ,

ANSWER: Following hardware parts and software are requested: SIWAREX MS module, S7-200 CPU, SIWATOOL MS software, RS232 cable, computer with Windows XPor higher and a calibration weight bigger than 5% of the sum of the nominal value of all load cells.

Requested parts:

S7-200 PLC


SIWAREX MS: 7MH4930-0AA01



SIWATOOL RS232 Cable:7MH4702-8CA


Software for SIWAREX MS: 7MH4930-0AK01
Adjustment weight Scale

The physical connection is as shown
below:

Start SIWATOOL MS.

Select COM1 as the communication interface.

Click Online

Resolution of SIWAREX MS

The weight is converted into a 16 bits value.
The value is comprised between 0 and 64000
The value is then transmitted as a signed integer to the SIMATIC PLC

INT has no comma and no units, the maximum value is 32767
For a 20kg scale you may use a resolution of 1 g:
Range 0 g to 20000 g

For a 40 kg scale you may use only a resolution of 10 g
Range 0.00 kg to 40.00 kg
The comma is not part of an integer and is only used for the display
à Choose resolution and comma before parameterization.

When the communication is established, follow the procedure below to make the adjustment.

Adj.digits 0 and Adj.digits 1: Accept the default values.
Adj.weight 1: Enter the value of adjustment (calibration) weight.
Characteristic Value: Sensor characteristic value. Indicated on sensor. Default value is 2 mV/V.

Limit frequency: Low-pass filter (0.05 Hz ~ 5 Hz).
If it is set to 5 Hz, the scale will respond quickly to the weight change; if it is set to 0.5 Hz, the scale will “move slowly”.


Step response of the digital low-pass filer for fg = 2 Hz

Depth of average value filter: n=2 ~ 255.
The average value filter ensures a stable weight value and prevents interference.
The weight is measured according to the average value of n weight values.
If n = 10, 10 weight values will be used for calculating the average value. The earliest value is discarded every 20 (or 33.3) milliseconds and the latest value will be added for the calculation.
Measuring time depends on the power supply frequency. For 50 Hz. select 20 ms and for 60 Hz select 33.3 ms.

After setting the parameters, click Send.

Set the weighing range of the scale and the step (resolution) of the scale.

Set the weight unit and the decimal point as follows:

Standstill time (ms) and Standstill range are used to monitor when the scale stand still.
If the weight change is lower than the specified range (standstill value) within the specified period (standstill time), then the scale stands still.

Negative and positive zeroing range.

This specification can be used to limit the effect of the function and therefore to protect the process. It is given in % of the max weighing range. Zeroing will be rejected if the current gross weight is too high or too low.

After setting the parameters, click Send.

Ensure that the scale is empty (not loaded) and click Adjustment zero valid (3).

Place the adjustment weight on the scale to adjust the range of the scale.

Click Adjustment weight 1 valid (4).

calibration.jpg
Calibration is complete.

Eventually you may save the calibration data’s into a file

Receive all data from the MS to the PC

During the tansmission from the Siwarex MS module to the PC, the following message-window appears:

Save the data as a Siwatool MS File:

Download of PDF-File

Calibrating SIWAREX MS with SIWATOOL MS ( 1476 KB )

If you have any problems or suggestions regarding the related products or documents, please feel free to contact:
Technical support for SIWAREX
Tel: +49 721 595 2811
Fax: +49 721 595 2901
E-mail: siwarex.hotline.aud@siemens.com
Website: http://www.siwarex.com